Higher oil produce utilised transformer oil regeneration device&comma vacuum purification and regeneration process&comma shield atmosphere and saves cash
Introduction&colon
This vacuum transformer oil filtering plant is introduced to the clientele at competitive costs&interval
The Double Phase Transformer Oil CZPT CZPT undergoes demanding quality handle assessments to make it devoid of all flaws&interval
The device is mainly used for electrical power office and industries to offer with different oils
This sort of as transformer oil&comma mutual oil&comma swap oil&comma dielectric oil and so on&period of time It also can be utilized for filtration of much more than 110KV substation stay line work on internet site&time period
In the meantime&comma as the bridge-variety vacuum linking technique&comma
Sequence ZYD oil purifier can be used as unbiased vacuum supply with functions of vacuum drying and vacuum oiling
In which is the collection ZYD employed&quest
This Double-phase Constant On-Website Transformer Oil Treatment method Plant Is Used for Purifying the Insulation Oil in all sorts of big Energy gear&comma which Voltage larger than 110kv&comma altitude more substantial than 500M&period
Characteristics&colon
Capability ranges from&colon 1000 LPH to 30000 LPH
Inlet CZPT Metal CZPT is easy to clean and used to capture keep coarse grime
Normal efficiency of &period5 &sol 1 CZPT right after good filter
Heat exchange through quite low particular power electric heaters
To increase the vacuum pumping pace&comma vacuum pump established in blend with rotary vane vacuum pump and roots pump are offered
Easy to function
Compact tools is also provided with pneumatic wheels for effortless transport on street
Duplex 3D stereo-evaporation engineering&comma reducing the liquid h2o very effectively
Distinctive removing impurities technology filtering by means of double FH trapezoidal network and absorbing by high polymer without the mechanical electrical power
British isles G technologies by which the trace drinking water that is display chain&comma this sort of as dissolved drinking water&comma can be eliminated impact
CZPT fiber infrared heating technique that can make the oil contains zero sum of ethyne following therapy
Adopts the double-infrared liquid automatic controller&comma delicate computerized strain protector and the higher efficient products for degas&comma so it is simple to operat
Our Oil Purifier Edge&colon
Comparing with the solitary-stage vacuum oil purifier&comma Sequence ZYD provides ROOTS vacuum technique&comma CZPT stage of separating program to improve the influence of purification which dewaters&comma degases and removes impurities a lot more rapidly&comma much more completely and make the oils limiting voltage-stand up to worth significantly larger&interval
This device also can take away totally free&comma soluble water&comma carbon&comma totally free and dissolved gases and particulate matters from insulating oil efficiently and swiftly&interval Sequence ZYD makes use of coacervation technological innovation&comma coalescing technology&comma separating engineering and refined purification technological innovation&period
Optional Features&colon
An exhaust condenser to evaluate the extracted water
Condenser is geared up to settle the most unstable oil fractions which may well distil back again to the column
Electronic temperature measurement
Electronic precision vacuum gauge
Electronic circulation meter
Electronic in line dampness articles meter
Ionic response columns to get rid of the acidity from the oil
Audio &sol Visible fault annunciation Technique
PLC handle program
Mobile Trailers can be presented
Fully-enclosed and Semi-enclosed for climate-evidence are obtainable
Index after purification
H2o content≤ 5ppm
Gas content≤ &period1&percnt&lpar by volume&rpar
Acetylene content material&colon
Breakdown voltage&geq 75KV &lparSpherical polar&rpar
Particle qty in 100ml oil≤ five hundred &lpar5-50 micron&rpar&comma &lpar0 for &geq a hundred micron particle&rpar&interval
Dielectric loss tgδ ≤ &period3&percnt &lpar90° C&rpar
Acid worth ≤ &period1mgKOH&solg
Parameters | Device | ZYD-thirty | ZYD-50 | ZYD-one hundred | ZYD-a hundred and fifty | ZYD-two hundred | ZYD-250 | ZYD-300 | |
Stream Charge | L&solh | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Operating vacuum | MPa | -&period08 ~ -&period099 | |||||||
Operating Force | MPa | ≤0&period3 | |||||||
Temperature Variety | °C | 20 ~ 80 | |||||||
Power | A few Section 50Hz&comma380V &lparor as needed&rpar | ||||||||
Working Noise | dB&lparA&rpar | 70 | 70 | 70 | 75 | 75 | seventy five | 75 | |
Heating Power | KW | 28 | thirty | forty five | sixty | seventy five | 90 | 120 | |
Complete Electrical power | KW | 35&period5 | 37&period5 | 52&period5 | 71&period4 | 86&period5 | 102&period5 | one hundred thirty five | |
Inlet&solOutlet | mm | φ25 | φ32 | φ42 | φ50 | φ50 | φ60 | φ60 | |
Bodyweight | Kg | 600 | 800 | 1050 | 1400 | 1800 | 2000 | 2200 | |
Total | Duration | mm | 1050 | 1100 | 1200 | 1450 | 1600 | 1800 | 1900 |
Width | mm | 750 | 800 | 950 | 950 | 1100 | 1200 | 1200 | |
Height | mm | 1350 | 1400 | 1500 | 1650 | 1800 | 1900 | 1900 |